MachineryOffers

Hantek HSA2030A Handheld Digital Spectrum Analyzer Portable Field Strength Meter 9kHZ 3.2GHZ AC Connected USB Interface HLX

Product details
Scanning (tracking) points:Chapter 461Frequency Resolution:1 Hz
model:HSA2030Apayment terms:L/C, Western Union, D/P, D/A, T/T, MoneyGram
Number of markers:4pay:TT
brand:Hantec-3dB Bandwidth:10Hz to 1MHz, 1-3-10 sequence
Frequency Range:9KHz~3.2GHz AC couplingOrigin:Guangdong, China
Reference frequency:10 MHzport:Shenzhen
Number of traces:4MOQ:1

Hantek HSA2030A Handheld Digital Spectrum Analyzer Portable Field Strength Meter 9kHZ 3.2GHZ AC Coupled USB Interface

HSA2030 series

Frequency range: 9KHz~3.2GHz; best sensitivity: -161dBm; RBW: 10Hz to 1MHz. High-protection portable design, sturdy and durable, can be used in the laboratory, more suitable for field mobile use Built-in large-capacity lithium battery, can work for more than 4 hours. 18650 rechargeable battery. USB/LAN communication, convenient for remote control. 5.6-inch bright color display, 640*480 resolution, clear waveform display.

feature

· Frequency range: 9KHz-3.2GHz (adjustable to 9KHz) AC coupling

Best Sensitivity: -161dBm RBW: 10Hz to 1MHz

· IP-51 high protection portable design, sturdy and durable, can be used in the laboratory, more suitable for mobile use in the field.

·Built-in large-capacity lithium battery, can work continuously for more than 4 hours. 18650 rechargeable battery.

· 5.6-inch bright color display, 640*480 resolution, clear waveform display.

· HSA2000 series spectrum analyzer has the lowest DANL and SSB phase noise and the narrowest RBW. Greatly enhanced the ability to identify stray signals and noise signals.

· Optional FM/AM modulation analysis including carrier power, modulation rate, AM depth/FM deviation, SINAD and carrier frequency offset.

• Standard spectral characteristics. It can analyze the signal time stability and accurately find out the cavity signal in the communication system.

· Powerful field strength test function, suitable for testing transmitters, base stations, and antenna coverage sites. It can display field strength or power density. Users can also use the amplitude offset function to calibrate gain or loss.

· HAS2000 series has the least RBW among analyzers of the same level, and can easily confirm, distinguish and measure two similar signals.

· 5.7-inch high-brightness color display, accurate, bright and clear internal and external tracks, no need to move to a shading place for work.

· Short scanning time. It quickly captures data and helps locate and identify irregular transient disturbance signals, optimizing test time and accuracy.

· Adopt advanced built-in battery management system. The standard configuration is a large-capacity 7800mAh lithium battery, supporting 6 18650 battery packs, which can ensure more than 4 hours of on-site measurement work.

· Sturdy and compact mechanical structure, tightly sealed with rubber sleeves, suitable for harsh on-site working environments.

· Integrated USB Host & Device, support U disk storage, optional WIFI/LAN, convenient for networking and remote control.

· The upper computer software can realize the management and storage of test data.

· HSA2000 series field measurement application.

parameter

parameter

Model

HSA2030A

HSA2030B

frequency

Frequency Range

9KHz~3.2GHz AC coupling

9KHz~3.2GHz AC coupling 5M~3.2GHz TG

frequency resolution

1 Hz

reference frequency

10 MHz

Frequency Reading Accuracy

±(frequency indication*frequency reference uncertainty+1%*span+20%RBW+cursor resolution+1Hz)

Internal 10MHz reference

accuracy

aging rate

±1ppm/year (0℃~50℃, refer to 25℃)

temperature stability

±1ppm/year

Mark resolution

(frequency span)/(sweep points-1)

Resolution Bandwidth (RBW)

-3dB bandwidth

10Hz to 1MHz, 1-3-10 sequence

accuracy

±5% RBW=10Hz~1MHz nominal value

Resolution Filter Shape Factor

<5:1 nominal

Video Bandwidth (VBW)

-3dB bandwidth

1Hz to 1MHz, 1-3-10 sequence

accuracy

±10% VBM=1Hz~1MHz nominal value

Displayed average noise level (normalized to 1Hz)

9K~1MHz

preamp off

-108dBm, typical -127dBm

1MHz~10MHz

-128dBm, typical -146dBm

10MHz~500MHz

-142dBm, typical -146dBm

500MHz~2.5GHz

-141dBm, typical -145dBm

2.5GHz~3.2GHz

-140dBm, typical -144dBm

9K~1MHz

preamplifier on

-131dBm, typical -150dBm

1MHz~10MHz

-148dBm, typical -163dBm

10MHz~500MHz

-161dBm, typical -164dBm

500MHz~2.5GHz

-159dBm, typical -162dBm

2.5GHz~3.2GHz

-158dBm, typical -161dBm

SSB Phase Noise

Carrier offset (20℃~

30℃,500MHz

Center frequency)

10K

< -92 dBc/Hz, typical -95 dBc/Hz

30K

< -93 dBc/Hz, typical -96 dBc/Hz

100,000

< -95 dBc/Hz, typical -97 dBc/Hz

1 MHz

< -117 dBc/Hz, typical -119 dBc/Hz

Scan time

scope

Span>100Hz

2 milliseconds to 1000 seconds

Span=0Hz

600 ns to 200 s

scan mode

continuous, single

trigger source

free run; video; external

trigger slope

Positive or negative edge selectable

trigger delay

Span=0Hz

±12ms to ±12s nominal

frequency counter

Counter resolution

1 Hz

accuracy

±(marker frequency × frequency reference uncertainty + counter resolution)

Level display range

Log scale and units

1 to 10 dB/div in steps of 1, 2, 5, 10 dB, displaying 10 divisions

Linear Scale and Units

0 to 100%, 10 grid display

proportional unit

dBm, dBmV, dBuV, Watts, Volts

scan (trace) points

Chapter 461

number of marks

4

detector

Normal, Pos Peak, Damping, Neg Peak, RMS

Number of traces

4

trace function

Clear/Write, Max Hold, Min Hold, Average, Check, Off

Liquid level measurement error

±1.5dB (excluding input VSWR mismatch)

20~30℃, peak detector, preamplifier off, input signal -50dBm to 0dBm

reference level

Predetermined area

-100dBm to +30dBm, step size 1dB

set resolution

logarithmic scale

0.01dB

linear scale

Almost Logarithmic (2.236µV to 7.07V)

amplitude

Maximum Safe Input Level

average continuous power

+33dBm

DC input voltage

50V DC

Measuring range

9KHz~2MHz

Displayed Average Noise Level (DANL) to +10dB

2MHz~3.2GHz

Displayed Average Noise Level (DANL) up to +20dB

Input attenuator range

0 to 51dB, 1dB step

spurious response

Second Harmonic Distortion (SHI)

<65dBc, 50MHz to 3.2GHz (mixer level -30dBm, attenuator = 0dB, preamplifier off, 20℃~30℃)

third order

Intermodulation (TOI)

50~300MHz

+8dBm, third-order intermodulation products: 2 x -20dBm; frequency interval 100KHz: attenuation = 0dB; preamplifier off, 20℃~30℃

300MHz~3.2GHz

+10dBm

Input related spurs

<-75dBc, (input mixer=-30dBm)

intrinsic residual response

<-90dBm, typical -98dBm (input terminated and 0 dB RF attenuation, preamp off)

RF input VSWR

(at tuning frequency)

10MHz to 3.2GHz

<1.5:1, nominal attenuator setting 10~20dB

10MHz reference/external trigger input

Reference input frequency

10 MHz

Reference input amplitude

0~10dBm

trigger voltage

5V TTL level

Connector and Output Impedance

Type N female; (50Ω)

FAQ

A: Payment terms:

T/T, Western Union, Paypal, Bank Transfer

B: Shipping:

1. By EMS, DHL, FedEx, TNT, UPS or other express.
2. By your own forwarder.
3. Buyers can choose the desired shipping method when ordering.

Three: After-sales service:

All products are inspected and packed in good condition before shipment.

D: Delivery time:

After payment, general orders will be shipped from our factory within 3-5 working days.

customer service

Please contact us by email or phone and we will do our best to help you
China working hours Monday to Friday 9:30-18:30 online service to help buyers solve problems.

Welcome friends from all over the world to visit us!

VIEW MORE