Voltage: | 220v / 380v; | Warranty: | 1 year; |
Motor power(Kw): | 7.5-37; | Brand Name: | Lanphan; |
Supply Ability: | 1000 Set/Sets per Month; | After-sales Service Provided: | Video technical support,Online support; |
Port: | Shanghai, Tianjin, Qingdao; | Place of Origin: | Henan China; |
After Warranty Service: | Video technical support,Online support; | Certification: | CE; |
Weight(Kg): | 1700-8500; | Feature: | industrial centrifuge price; |
Dimension(L*W*H): | 1250*700*1020 mm; | Local Service Location: | United States; |
Drunm speed: | 1200 r/min; | Showroom Location: | United States; |
Drum diameter(mm): | 800-1600; | Power(W): | 1.1 - 5.5 kw; |
Key Selling Points: | Long Service Life; | Separation factor: | 650; |
Payment Terms: | L/C,T/T,Western Union,MoneyGram,Paypal; | Condition: | New; |
Type: | Distillation Equipment; | Packaging Detail: | Packing: carton or wooden case package, customized package is available.; |
Applicable Industries: | Manufacturing Plant,Food & Beverage Factory,Farms; | Product Type: | Plant; |
Name: | oil extraction centrifuge; | Weight: | 260 kg; |
The PP series centrifuge can be used to extract and filter centrifuges for cannabis and other plants. The series of centrifuges extract the active ingredients in plants through a built-in program, which is single-handed, easy to use and large in capacity.
The machine adopts a closed structure, and the seal is made of PTFE; the explosion-proof motor, frequency changer, PLC, touch screen and other devices can be used to achieve the sealed explosion-proof requirements.
Model | Drum diameter mm | Drum height(mm) | Volume(L) | Revolving speed (r/min) | Motor Power(KW) | Size(mm) | Weight(KG) |
PP-15 | 300 | 250 | 15 | 2000 | 1.1 | 950*500*480 | 210 |
PP-25 | 300 | 350 | 25 | 2000 | 1.5 | 950*500*580 | 220 |
PP-45 | 450 | 300 | 45 | 1500 | 2.2 | 1250*700*760 | 450 |
PP-60 | 450 | 400 | 60 | 1500 | 3 | 1250*700*860 | 470 |
PP-85 | 600 | 300 | 85 | 1250 | 3 | 1500*900*950 | 970 |
PP-110 | 600 | 400 | 110 | 1250 | 4 | 1500*900*1050 | 1000 |
PP-140 | 600 | 500 | 140 | 1250 | 5.5 | 1500*900*1150 | 1030 |
PP-15 Charge per batch around 5Kg(10 pound) Amount of ethanol each time around 30L(8 gallon)
PP-25 Charge per batch around 8Kg(18 pound) Amount of ethanol each time around 40L(11 gallon)
PP-45 Charge per batch around 14kg(30pound) Amount of ethanol each time around 85L(23 gallon)
PP-60 Charge per batch around 20kg(45pound) Amount of ethanol each time around 105L(28 gallon)
PP-85 Charge per batch around 25kg(55pound) Amount of ethanol each time around140L(37 gallon)
PP-110 Charge per batch around 35kg(75pound) Amount of ethanol each time around175L(46 gallon)
PP-140 Charge per batch around 45kg(100pound) Amount of ethanol each time around 210L(55 gallon)
Working principles
The operator fills the filter bag with ground plant material and places it in the machine. Then, ethanol is added until the plant material is submerged, and the program is set to bidirectional (positive and reverse alternating) rotation to fully extract the active ingredients in the plant. The bottom valve is opened to release the extract, and then the plant material is subjected to high-speed rotary exhaustion of fluid to completely recover the extract.
Environmental, transportation, storage requirements
1 Working environment: temperature -50 ° C -50 ° C; air relative humidity is not more than 85%.
2 Transportation: Centrifuges must not be rolled and inverted during shipment, and must not be stacked to prevent rainwater intrusion.
3 Handling: The centrifuge must be hoisted according to the position of the center of gravity of the centrifuge during the handling process. The machine is equipped with 4 lifting rings. When lifting, try to keep the level of the centrifuge. Do not roll and invert.
4 Storage: The centrifuge should be placed at a temperature of 0-40 ° C, the relative humidity of the air is not more than 85%, and there is no corrosive medium to avoid the place.
The centrifuge must be kept by a person before installation and use to ensure the integrity of the centrifuge. The technical status and installation of the centrifuge should be confirmed by the manufacturer before operation.
Machine installation and adjustment
1 Installation Precautions
1.1 The machine must be kept in storage before and after installation. Pay attention to the moisture protection of the motor and pay attention to the protection of the electronic control system.
1.2 Safety must be taken during lifting to prevent the machine from being damaged by collision.
1.3 The centrifuge installation must be horizontal and the reference surface is the upper plane of the machine base (level ≤ 3mm).
1.4 There should be sufficient space between the equipment and other equipment installed adjacent to the centrifuge and the centrifuge to prevent the machine from colliding with it and causing damage or noise, and to facilitate inspection and maintenance of the machine.The space required for the use and maintenance of the centrifuge should be considered during the installation position of the centrifuge.There should be a pedestrian passage of not less than 1 meter around the centrifuge main unit. There must be more than 2 meters of assembly and disassembly maintenance space above the centrifuge main unit.
1.5 Because the centrifuge has slight vibration during high-speed operation, the pipe (feeding pipe, outlet pipe, washing pipe, exhaust pipe, cable pipe, etc.) connected to the centrifuge must be flexibly connected, and the connection must be reliable. Sealed or insulated to ensure no leakage and safe use of electricity. The diameter of the external outlet pipe shall not be less than the diameter of the machine outlet pipe, and shall not have dead bends or blockages. The pipe arrangement shall be lower than the height of the outlet pipe outlet and have a certain height difference so that the liquid discharge is unblocked.
The size of pipe interface :
1.6 Select the appropriate filter cloth type to make the filter bag according to the characteristics of the separated materials. And ensure the filter bag and the drum body have a good fit according to the filter bag provided by the manufacturer.
1.7 The electrical wiring is connected by an electrician according to the electrical control schematic diagram of the PP series centrifuge to wait for the operation and adjustment of the centrifuge.
1.8 After the centrifuge is installed, turn on the motor power, adjust the tension of the motor's V-belt, and prepare for the test run.
Warning
2.1 The cover must be covered and locked before the machine is running!
2.2 Do not open the cover when the machine is running!
2.3 It is strictly forbidden to use rigid connection among the feeding tube, the washing tube and the liquid discharging tube on the main machine of the centrifuge, so as not to affect the vibration damping system of the main machine itself and damage the machine.