feature
* 48 pressure ranges from ±25 mbar to 1,400 bar
(±1.69 psi to 20,000 psi / 2.5 KPa to 140 MPa)
* 1 year total uncertainty down to 0.05% Full Scale (FS)
Over the temperature range of -10°C to +50°C
* Full calibration record with calibration due
countdown display
* Rugged handheld design with backlit high contrast
exhibit
* Leak Test, Tare, Max/Min and Filters
* Hazardous area (intrinsically safe) version available
* Optional remote plug and play pressure and
Resistance Temperature Detector (RTD) Sensors
*Optional pneumatic and hydraulic hand pumpDPI 705E Improves Test Efficiency
* Start use. No warm-up time required.
* 19 pressure measurement units (see below)
* 1, 3 or 5 minute leak test
* Impact resistance, sealing level IP54
* Large digit high contrast LCD with backlight
* Optional carrying case with belt loop
* Optional magnetic/loop lanyard
* Long battery life
* Integrated table frame and clothes hanger
calibration
with optional pneumatic or
hydraulic hand pump, the DPI 705E Series provides
Simple, low-cost calibration solution.
Battery
* 4 x AA Alkaline/NiCd/NiMH Batteries
* Power-saving design, can be used for 8 hours each time
days, 6 days a week, for 1 year, using a set of
Battery.
exhibit
16mm LCD with ±99999 readings
pressure range
Internal and remote sensors are supplied with pressure connectors as detailed below:
* 25 mbar – 200 bar (10 inH2O - 3000 psi / 2.5 kPa - 20 MPa): G1/8 BSP female thread
* Differential reference port: Legris 4 mm tubing adapter
* ≥350 bar (5000 psi / 35 MPa): Autoclave 9/16 x 18 UNF male thread
special function
pressure unit
mbar, bar, Pa, hPa, Pa, MPa, psi, lb/ft2, kgf/cm2, kgf/m2,
mmHg(0°C), mHg(0°C), inHg 0, mmH2O, cmH2O, mH2O,
inH2O (4°C, 20°C), ftH2O (4°C, 20°C)
Calibration certificate
* Standard bar, psi and kPa
* Available with optional UKAS accredited calibrationleak test
Used to determine whether there is a leak in the system
Changes in pressure over time were recorded.
Leak testing can also be used with RTD sensors to record
Changes in temperature over time.
User defined 1, 3 or 5 minute leak test.
biggest smallest
Capture maximum and minimum readings
Peak hold mode.
zero
Zero pressure correction (pressure gauge/differential pressure sensor)
tare weight
0 to 100% FS Temporary Zero Offset Capability
Subtract the current reading from the subsequent
Measurement.
filter
Enable filtered pressure readings with display scrolling
Average of the last 10 measurements. provide more
Stable readings for noisy measurements.
alarm
User adjustable; high and low pressure alarms
Visual (bell icon, pressure readout and backlight flash)
and sound warning for 60 seconds.
Hazardous Area Certification
* ATEX, IECEx, NEPSI, ECASEx (order code "H1")
* INMETRO (order code "H2")
* IS Class I, Groups A, B, C and D, T4 Ex ia; Class I, Zone 0,
AEx/Ex ia IIC T4 Ga (-10°C ≤ Ta ≤ +50°C) CSA compliant.
157-92, UL 913 (7th Edition), CAN/CSA-C22.2 No. 60079-
0:2018, CAN/CSA-C22.2 No. 60079-11:2012, ANSI/UL
60079-0:2018 and ANSI/UL 60079-11:2012.
* Ex ia IIC T4 Ga (-10°C ≤ Ta ≤ +50°C) according to ATEX IEC
60079-0:2017 and EN 60079-11:2011