MachineryOffers

Full spectrum chromatography HPLC for cbd hemp oil extraction remediation separation mother liquor

Product details
Brand Name:hempmaster;Item:Full spectrum;
Test item:cbd oil;Packaging Detail:Qualified wooden cases Full spectrum chromatography for cbd oil extraction HPLC hemp oil remediation separation mother liquor;
Type:Electronic analyzer;Place of Origin:Shanghai China;
Application:Test tool;main use:Component testing;
Supply Ability:5 Piece/Pieces per Month Full spectrum chromatography for cbd oil extraction HPLC hemp o;Product name:HPLC;
brand Name:hempmaster;After-sales Service:Free spare parts;
Service:Service Overseas;Port:shanghai;
Usage:Industrial test;Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram;
Company Information

 

 

 

 

 

Full spectrum chromatography HPLC

Product Description

 

 

LC600B High pressure constant current infusion pump

 Infusion mode

 Micro-volume series double plunger

 Maximum hydraulic pressure

 0~9999Psi

 Flow Setting Range

0.001~9.999mL/min(Flow regulation with 0.001 mL/min step size)

 Error Value of Flow Setting Value

≤0.5%

 Flow stability error value

≤0.2%RSD

 Gradient error value

±1%(Gradient of 0-100% Water/Acetone Aqueous Solution 2 Solution)

 pressure fluctuation

Less than 15 Psi (flow rate 1 mL/min, pressure 600-1600 Psi)

 Pump tightness

The pressure is 5400 Psi, the time is 10 minutes, and the pressure drop is less than 400 Psi.

Size

W260×H130×D420mm

Weight

11kg

Use ambient temperature range

4~40℃

SPD600B Ultraviolet-Visible Variable Wavelength Detector

 Wavelength range

190nm~700nm

 Error value of wavelength indication

≤±1nm

 Error value of wavelength repeatability

≤±0.1nm

 Dynamic noise

≤ ±0.75×10-5AU(methanol,1ml/min,254nm,20℃)

 Static noise

≤ ±0.5×10-5 AU(Empty pool, response time 1 second,20℃)

Dynamic baseline drift

≤±1×10-4AU/h(methanol,1mL/min,254nm,20℃)

Static baseline drift

≤ 5×10-4 AU/h(Empty pool, response time 1 second, 20℃)

Linear range

≥104

Minimum detection concentration

≤1×10-9g/mL(naphthalene/methanol solution)

Qualitative repeatability

RSD6≤ 0.1%

Quantitative repeatability

RSD6≤ 0.5%

Spectral bandwidth

6nm

Flow Pool Volume

8μL

Optical path

10mm

Time Programming Function

Yes

Size

W260×H130×D420mm

Weight

11kg

Use ambient temperature range

4~40℃

 

 

Detailed Images

 

 

Company Information

 

Certifications

 

Packaging & Shipping

 

 
Our Services

 

1. Pre-service

24 Hours online service for your consult.
Help choose right model and a series of service, person advise.
2. After sale service
--1 year warranty service and all life maintenance.
--Technical Engineer are available for oversea training.
--Free change for some parts
--Remote control technical consult
--Maintenance plan

contact us

 

VIEW MORE