Brand Name: | hempmaster; | Item: | Full spectrum; |
Test item: | cbd oil; | Packaging Detail: | Qualified wooden cases Full spectrum chromatography for cbd oil extraction HPLC hemp oil remediation separation mother liquor; |
Type: | Electronic analyzer; | Place of Origin: | Shanghai China; |
Application: | Test tool; | main use: | Component testing; |
Supply Ability: | 5 Piece/Pieces per Month Full spectrum chromatography for cbd oil extraction HPLC hemp o; | Product name: | HPLC; |
brand Name: | hempmaster; | After-sales Service: | Free spare parts; |
Service: | Service Overseas; | Port: | shanghai; |
Usage: | Industrial test; | Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram; |
Full spectrum chromatography HPLC
LC600B High pressure constant current infusion pump | |
Infusion mode | Micro-volume series double plunger |
Maximum hydraulic pressure | 0~9999Psi |
Flow Setting Range | 0.001~9.999mL/min(Flow regulation with 0.001 mL/min step size) |
Error Value of Flow Setting Value | ≤0.5% |
Flow stability error value | ≤0.2%RSD |
Gradient error value | ±1%(Gradient of 0-100% Water/Acetone Aqueous Solution 2 Solution) |
pressure fluctuation | Less than 15 Psi (flow rate 1 mL/min, pressure 600-1600 Psi) |
Pump tightness | The pressure is 5400 Psi, the time is 10 minutes, and the pressure drop is less than 400 Psi. |
Size | W260×H130×D420mm |
Weight | 11kg |
Use ambient temperature range | 4~40℃ |
SPD600B Ultraviolet-Visible Variable Wavelength Detector | |
Wavelength range | 190nm~700nm |
Error value of wavelength indication | ≤±1nm |
Error value of wavelength repeatability | ≤±0.1nm |
Dynamic noise | ≤ ±0.75×10-5AU(methanol,1ml/min,254nm,20℃) |
Static noise | ≤ ±0.5×10-5 AU(Empty pool, response time 1 second,20℃) |
Dynamic baseline drift | ≤±1×10-4AU/h(methanol,1mL/min,254nm,20℃) |
Static baseline drift | ≤ 5×10-4 AU/h(Empty pool, response time 1 second, 20℃) |
Linear range | ≥104 |
Minimum detection concentration | ≤1×10-9g/mL(naphthalene/methanol solution) |
Qualitative repeatability | RSD6≤ 0.1% |
Quantitative repeatability | RSD6≤ 0.5% |
Spectral bandwidth | 6nm |
Flow Pool Volume | 8μL |
Optical path | 10mm |
Time Programming Function | Yes |
Size | W260×H130×D420mm |
Weight | 11kg |
Use ambient temperature range | 4~40℃ |
1. Pre-service
24 Hours online service for your consult.
Help choose right model and a series of service, person advise.
2. After sale service
--1 year warranty service and all life maintenance.
--Technical Engineer are available for oversea training.
--Free change for some parts
--Remote control technical consult
--Maintenance plan