Measurement Range: | 380nm~780nm; | Characteristic Concentration: | 0.02μg/ml/1%; |
Base Line Stability: | ≤0.002A/30min; | Delivery Detail: | within one week; |
Wavelength Accuracy: | ±0.15nm; | Wavelength Receptivity: | ≤0.04nm; |
Brand Name: | BIOBASE; | Payment Terms: | L/C,D/A,D/P,T/T; |
Detection Limit: | 0.004μg/ml; | Place of Origin: | Shandong China; |
Size: | 550*450*300; | Port: | qingdao; |
Supply Ability: | 1000 Unit/Units per Quarter; | Measurement Repeatability: | ≤0.5%; |
Focal Length: | Contat; | Packaging Detail: | wooden package; |
Weight: | 65; | Model Number: | BK-AA4530F; |
Wavelength Range: | 130-650nm,190 - 900nm; | Grating: | 1800 lines/mm; |
BK-AA4530F Atomic Absorption Spectrophotometer
Features:
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
2. Integrated floated optical platform design improves the optical system shock resistance stable.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
4. Position adjusting: the flame burner can be set on the best position automatically.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background calibration.
8.Measuring method: flame absorption method and emission method.
9.Result printing: parameter, data result and diagram.
10. Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.
Model | BK-AA4530F |
Wavelength Range | 190 – 900nm |
Wavelength Accuracy | ±0.15nm |
Wavelength Receptivity | ≤0.04nm |
Base Line Stability | ≤0.002A/30min (Cu) |
Characteristic Concentration | 0.02μg/ml/1% (Cu) |
Detection Limit | 0.004μg/ml (Cu) |
Measurement Repeatability | ≤0.5% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Efficient glass atomizer |
Lamp stand | 8 |
D2 background Calibration | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Power Supply | 220V, 50/60Hz |
Packing Size(mm) | 850 x 700 x 750(Main instrument) 950 x 620 x 1020( Accessories ) |
Gross Weight(kg) | 105Kg (Main instrument) 100Kg ( Accessories ) |
Standard Accessories | PC workstation HP inkjet printer Oil free Air compressor Acetylene reducing valve Cu Hollow cathode lamp Air filter |
Optional Accessories | Graphite Furnace Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)
|