ICooler 9 raising the cryogenic circulation pump is the basic constant temperature equipment in the laboratory, providing a small and economical cooling solution for the laboratory. The compact structure design is very convenient to use in the ventilator and on the desktop, the cooling cycle pump adopts the pressure suction pump with centrifugal force, the pressure / suction =0.3/0.2bar (head 5m), and the flow 22L/min. Use the maximum temperature of up to 100 degrees.
1. Product characteristics:
Waterproof keyboard design, highlighting LED display;
Small size, can be directly placed on the desktop and fume hood.
Environmental protection refrigerant, non-toxic pollution;
Convenient infusion and drainage;
Protection function, high voltage protection and over current protection.
Pump pressure and flow automatically adapt to external loads, effectively protecting external equipment, especially glass parts.
Warning lights and sounds are reminded at the same time, all kinds of alarm codes are displayed directly, and the error points can be directly determined.
Automatic storage of temperature
Advanced proportional refrigeration control technology and good temperature stability.
CIT refrigeration technology, high temperature even at 100 degrees centigrade start refrigeration at any time.
The maximum temperature and minimum temperature setting of the machine can be limited.
Buzzer can be silent or sound
Alternative mode of operation
1) mode 1: when the power supply is disconnected during the operation of the equipment, the next power on device is in a normal stop state, and the setting value can be changed.
2) mode 2: when the power supply is disconnected during the operation of the equipment, the next power on device will run automatically, and the setting value can be changed.
3) mode 3: when the power supply is disconnected during the operation of the equipment, the next power on device will run automatically, and the setting value can not be changed.
Pt100 temperature sensor for single point and two point temperature calibration.
Refrigeration heating function and circulation function can be controlled independently or at the same time.
The serial number of the device can be checked by software
Maintenance free pressure / suction pump, fiber and metal particulate matter, long life.
An intuitive liquid level window allows users to observe liquid level.
The water tank is set up to protect the overflow.