usage: | Oxygen concentration detection | range of working temperature: | 0°C to +50°C |
Working Humidity Range: | 0% to 99% RH, non-condensing | Types of: | gas sensor, oxygen sensor |
Temperature compensation: | <2% O² equivalent change from 0°C to 40°C | Response time: | <5 seconds (T90) |
brand: | Xunster | payment terms: | L/C, D/P, T/T |
Working pressure range: | 0.5 bar~2.0 bar | Measuring range: | 0~100 Vol.% O² |
output: | 9 mV to 13 mV in air, 0 to 100% linear output | describe: | Oxygen Sensor |
model: | XST-YQ-AO-02 | place of origin; place of origin: | Guangdong, China |
AO-02 oxygen sensor is designed for various instruments related to oxygen detection, such as motor vehicle exhaust gas detection equipment, exhaust gas environmental protection detection equipment, oxygen index detection equipment, etc., and its use is limited to system monitoring. The data presented in this document is valid for 3 months from the date of manufacture of the sensor at 20°C, 50% RH and 1013 mBar. Please operate the oxygen analyzer and replace the oxygen sensor strictly according to the instructions.
Measurement | |
working principle | partial pressure electrochemistry |
output | 9 - 13 mV in air |
Measuring range | 0 - 100% volume oxygen |
Response time (T 90 ) | <5 seconds |
Response time (T 99.5 ) | <40 seconds |
baseline shift | <20 microvolts |
Linearity | Linear 0-100%Vol.O2 |
electric | |
Temperature compensation | <2% O2 equivalent change from 0 °C to 40 °C |
external load resistor | ≥ 10 ohms |
Connector | 3-pin Molex connector (MOLEX 22-29-2031) |
Recommended mating parts | Molex Tee Housing (MOLEX 22-01-2035) Molex Crimp Terminals (MOLEX 08-45-0110) |