DW-GC1290 LCD Touch Screen Cheap Gas Chromatograph

Product details
Temperature accuracy:± 0.02℃;Payment Terms:L/C,T/T,Western Union,MoneyGram,Paypal;
Packaging Detail:Standard Export packaging (Safe and pure English);Port:shanghai port;
Detection limit:≤8x10-12g/s (n-hexadecane);Noise:≤3x10-14A;
Temperature range:Ambient temperature +7℃ ~ 420℃ (in 1℃ increment);Supply Ability:1000 Piece/Pieces per Month;
Cooling time:350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient;Programmed temperature setting:0.1℃~80℃/min (in 1℃ increment);
Brand Name:Drawell;Model Number:DW-GC1290;
Baseline drift:≤0.6%FS;Drift:≤1.5x10-13A/h;
Place of Origin:Shanghai China;
   Gas Chromatography  
 
Model# DW-GC1290
DescriptionEPC(electronic pneumatic control)
 7 inch touch screen display
Sample Introduction Systemsample injector and evaporation chamber
Column OvenTemperature rangeAmbient temperature +7℃ ~ 420℃  (in 1℃ increment)
Temperature accuracy ± 0.02℃
Cooling time350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting0.1℃~80℃/min (in 1℃ increment)
Program ramps20 ramps in total (99 ramps available with control workstation)
Size (L*W*H)284*280*241mm(inside)340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit≤8×10/12g/s (n-hexadecane)
Drift≤1.5×1//13A/h
Noise≤3×10/14A
Linearity range≥106
Flame Photometric Detector
(FPD)
Detection limit≤8×10/13g/s(P) ; ≤8×10/11g/s(S)
Drift≤2×10/11A/30min
Baseline noise≤5×10/12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit≤5×10/12g/s(N) (Azobenzene)
            ≤5×10/13g/s(P)  (Malathion)

 

 

Features:

. Control system: designed for monitoring and controlling the instrument via the computer.
. Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by “control system”)
. Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
. Column oven supports quick heat-up and rapid cool-down with automated back-door opening.
. Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.
. High sensibility and stability detector.
. 2 independent and analog signals output.
. M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)

 

Electronic pneumatics control system

Flow rate: 200ml/min (N2), 1000ml/min (He)
Flow rate accuracy: ±5%
Flow rate repeatability: ±0.35%
Split ratio: 0-5000(He), 0-1000(N2)
Inlet temperature: 0-420℃

 
Gas chromatography and accessories:

Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ FPD/ NPD
 