MachineryOffers

2019 Oilfield Effective- friendly Equipment Flare Ignition Device Widely Used In Oil and Gas Drilling

Product details
Weight:200kg;Product Name:Electrical Equipment Protection Device;
Industry:Oil and Gas;Warranty:1 Year;
Condition:New;Temperature:-40℃~55℃;
Port:Tianjin,Qingdao,Shanghai,Lianyungang,Guangzhou,Ningbo;Dimension(L*W*H):300*300*2100mm;
Payment Terms:L/C,T/T,Western Union,MoneyGram,Cash,Paypal, Trade Assurance;Grouped Equipment:Liquid Gas Separator;
COLOR:Red or according to the requirement;Place of Origin:Henan China (Mainland);
Supply Ability:50 Set/Sets per Month;Company Nature:Factory;
Certification:ISO;Packaging Detail:Ignitor: 1.Main body naked into the container.Other parts fixed with iron frame 2.Transport to the port. 3.Shipping to the desitination port by sea. Remark:Can package according to the order requirement.;
After-sales Service Provided:Video technical support,Online support,Field installation, commissioning and training,Field maintenance and repair service;Product Usage:Elimination of Harmful Gases;
Brand Name:STAR;Aoolication:Oil Drilling,Refinery and Natural Gas Gathering Station;
Raw material:Steel;Ignition Method:Electronic;
Voltage:16;
Product Description

Product Application

Ignitor for liquid-gas separators is an environmentally-friendly discharge torch that is exclusively produced by our company. It is suitable for ignition of long distances and air and toxic gas burning placesthat  cannot be reached by humans.It is especially suitable for oil production(gas) overflow of gas or oil, naturral gas, and drilling operation in stationo gathering pipelines, and long-distance ignition of natural gas separated by liquid-gas separators during killing operations eliminate the unsafe factors of manual ignition. Avoid explosions that may occur when natural gas is mixed with air and H2S-containing gases that can harm humans and equipment.

Horizontal Igniter for burn the gas from well drilling discharged pipelines(Type:SDKX)

Verrical Igniter for Burn the gas from liquid-gas separator.(Type:YPD)

Flare Ignition Device Feature:

    1.Stainless steel burner torch

    2.Mature design with successful job site performance

    3.Conventional battery or solar battery

    4.Custom built available

Electrical Equipment Protection Device Tehnical Parameters
Fuel Tank
40L
Burner(Torch) Path:
DN200MM
Burner Height:
About 2m
Burner Height:
3m
Pressure Regulator Valve Set Outlet Pressure
≥0.5 Mpa
Electronic Ignitor Power:
DC
Remote Control Distance
30m
Electronic Ignitor Voltage:
16kW
Ignition Medium
Diesel
Electronic Ignitor Frequency:
100-1000beats/Min
Charging Voltage
~220V,50HZ
Ambinent Temperature:
-30℃~40℃
Ignition Frequency
≤10 Times/Second
Main Configuration
Combustion Cylinder
1
Fire Torch
1
Ignition Rod
1
Fire Tube
1
Control Box
1Set
Windshield
1
Fuel Injection Gun
1
Electrical Control Box
1
Oil Pipeline
1
Ignition Device Body
1(Including Torch,High-Energy Package)
Gas Pipeline
1
Ignition Control Box
1(There is a remote control,electronic control box key)
High Voltage Cable
30m
Cable Tray
1
Gas Hose
30m
Liquefied Gas Connection Pipeline
1(with 2 tube clip)
Remote Control
1
Pressure  Reducing  Valve
1
Products Display

Verrical Igniter Display

Horizontal Igniter

Certifications

Our Company was established in 2007,Obtained a business license,ISO,API and so on.

Packing & Delivery

Waiting for delivery

Ignitor for Well Drilling ready well, waitiing to be transport to the port.

Transport to the port

Container is transported to the port.

Sea Shipping

Container loaded on board, travel across to sea to the port of destination.

Our Company

Workshop Show

Factory Show

Team Show

The China Import and Export Fair

Foreign Exhibition

International Trade Service Team

Welcome friends from all over the world to come to visit our factory and guidance our work.

Related Products

Oil-Gas Separator

91.8% Response Rate

Crown Block

91.8% Response Rate

Mud Pump

91.8% Response Rate

FAQ
Problem
Reason
Solutions
1.After the controller is turned on, Ignition device does not ignite
1.Loss of battery
2.Output insurance blown
3.Cable and ignition cable broken
4.Possible ignition device is broken
5.Ignition conductive rod is damaged
6.High energy cable connector is not connected fastened
1.After charging, use again
2.Replace the same type of insurance
3.Check the connection wire and ignition wire
4.Contact after-sales service or repair
5.Check whether it is broken or replaced.
6.Close the ignition controller, check, check it ,then tighten the connection.
2.When the ignitor works, the front end of the conductive rod emits a sound of "pa,pa,pa...."
Ignition electric shock sound
Ignition electric shock sound
3.Igniter sparks at each connection
The connector is not tightened
Tighten(note that porcelain cannot be used too much)
4.Ignition controller output votage is too low
Maybe the voltage converter in the controller is faulty
Contact after-sale service or repair
5.Ignition controller charging deficiency
Maybe the controller charging system is faulty
Contact after-sale service or repair
Contact Us

If you have any question,please feel free to contact me,we are available 24 hours online to solve your problem.


VIEW MORE